Real-Time Blend Uniformity Testing: NIR Light in Pharmatech Blenders
In tablet and capsule manufacturing, blend uniformity is one of the most critical steps. If the active ingredient is not evenly distributed through the powder, each tablet may receive a different dose. The question is how, and at what stage, you know that the blend is really ready.
Blenders from UK-based Pharmatech, part of the Terriva group, can integrate an NIR/PAT system: a real-time monitoring system that uses light sensors to confirm, during blending, that the powder is well and evenly mixed.

The traditional way: stop, sample, wait
In most plants, blend uniformity is checked like this: the blender is stopped, the powder is sampled with a sampling thief from several points in the vessel, and the samples are sent to the laboratory for testing. Until the result arrives, production waits. In addition, blending time is usually fixed in advance by the validation, and not by what is actually happening in the current batch.

Tumble blender: gentle blending by gravity
Pharmatech MultiBlend blenders are tumble blenders: the vessel rotates and the powder blends gently by gravity.
Speed: 5–30 rpm, typically 5–25 rpm.
Fill level: 33%–66% of the vessel volume, with 50% as the optimum.
Interchangeable vessels: drums, IBCs, V-shells and double-cone vessels, of any size, on the same drive unit.
GMP design: stainless steel, smooth edges that are easy to clean, and CE marking.

How NIR works: a light beam that checks the blend
An NIR (near-infrared) sensor is mounted on the vessel and rotates with it. On every rotation, as the powder passes in front of the sensor window, a beam of light enters it. The light reflected from the powder is captured as a spectrum, a kind of chemical "fingerprint" of the blend at that moment. A new spectrum is recorded on every rotation, without stopping the blender and without opening the vessel.

When is the blend ready?
At the start of blending, the spectra differ from one another, because on each rotation the sensor "sees" a different composition. As the powder blends, the spectra become more similar. The software compares each spectrum with the previous ones and calculates the variability between them (for example, a moving standard deviation). When the variability drops and stabilises, that is the end point: the blend is uniform.

The benefits
Non-invasive measurement: the check is made through a window, without inserting a sampling thief into the powder.
No sample preparation: the measurement is fast and needs no laboratory preparation.
Real-time end point: the decision is based on the state of the blend itself, not only on a pre-set time.
Tracking excipients too: NIR can also track components such as magnesium stearate, not only the active ingredient.
In published studies, NIR monitoring shortened blending time in some cases compared with the fixed validated time. The result depends on the product, and the end-point threshold is set separately for each product.
Integrated into the blender control
Integration of NIR/PAT into the blender control system.
Control in line with 21 CFR Part 11, with an audited system, electronic signatures and user access management.
Electronic batch reports in PDF.

From the laboratory to production
The NIR/PAT option is available across the Pharmatech blender range:
MB005: vessels up to 5 litres, a benchtop laboratory blender (NIR possible).
MB015: vessels up to 30 litres.
MB100: vessels up to 100 litres, on a mobile frame.
MB400: vessels up to 300 litres.
MB1200A: vessels up to 750 litres.
MB2000A: vessels up to 1,000 litres, and custom blenders above that.
Want to see this with your product?
Trident, the representatives of Pharmatech in Israel, will be happy to help you choose the blender, vessels and NIR system that suit your formulation and your production volume. For more details: info@trident.co.il